1 / 6
$1,160.50
In stock
Free Standard shipping
Typically arrives in 4 business days
Quantity
- Transfers Load from UPS to Utility Power
- Supports OL5KRTHD & OL6KRTHD UPS Systems
- Single-Phase Power
Key specs
- Dimensions
- 17.0 x 3.4 x 4.9" / 433.0 x 86.5 x 125.0 mm
- Weight
- 8.8 lb / 4 kg
- Compatibility
- OL5KRTHD OL6KRTHD
- Input
- Terminal Block to UPS Input Terminal Block to UPS Output Terminal Block to Utility Power
- Input Voltage Range
- 200 to 240 VAC
- Maximum Input Current
- 63 A
Overview
Segue between UPS and utility power with the MBP63A2 2 RU Maintenance Bypass PDU from CyberPower. Move an electrical load from your UPS to utility power at the flick of a switch, with no disruption to connected equipment. Featuring a single-phase power design, this bypass PDU allows for easy maintenance of UPS systems, including battery replacement and installation. Accepting input voltages from 200 to 240 VAC at up to 63A, this power distribution unit outputs a nominal 208 VAC. Outputs include a terminal block and NEMA L6-20R and L6-30R receptacles, while inputs are comprised of three terminal block connections for UPS input, UPS output, and utility power.
Featuring a 2 RU form factor, the MBP63A2 can be installed horizontally or vertically in a server rack or as a tower. A steel case ensures durability in industrial environments, while 3.3' power and management cables allow for easy installation. Rack mounting hardware is also included. The MBP63A2 2 RU Maintenance Bypass PDU is compatible with CyberPower OL5KRTHD and OL6KRTHD UPS systems.
Power Distribution
Delivers AC power to servers, equipment, and connected devices via a power distribution unit.Maintenance Bypass
Qualified personnel can use the bypass feature to disconnect the PDU from the UPS without disrupting power to connected equipment. This feature allows connected equipment to operate seamlessly during maintenance periods, battery replacement, or UPS installation.Manual Bypass Switch
When the Manual Bypass Switch is turned to Normal, connected equipment is supplied by UPS output. When the Manual Bypass Switch is turned to Bypass, connected equipment is supplied by utility power.MBP Detection Cable
Communicates directly between the UPS and Maintenance Bypass PDU to safely coordinate the bypass switch operation. When the PDU bypass switch operation is initiated by removing the cover, the MBP Detection Cable sends a signal to the UPS to internally transfer to bypass mode to prevent UPS damage.Network-Grade Plugs and Outlets
Durable construction ensures the efficient distribution of power in demanding IT or industrial environments to servers, equipment, and connected devices.2 RU Form Factor with Mounting Hardware
The 2 RU form factor is made to be mounted horizontally or vertically in a standard server rack, on a wall, or in a tower configuration.Durable Metal Housing
Protects internal components and resists damage from impact or abrasions within challenging industrial environments, while also extending the life of the product.Specifications
1 groups · 16 specs
- Compatibility
- OL5KRTHD OL6KRTHD
- Input
- Terminal Block to UPS Input Terminal Block to UPS Output Terminal Block to Utility Power
- Input Voltage Range
- 200 to 240 VAC
- Maximum Input Current
- 63 A
- Nominal Output Voltage
- 208 VAC
- Outlets
- 1 x NEMA L6-20R 1 x NEMA L6-30R 1 x Hardwire Terminal Block
- Cord Length
- 3.3' / 1 m (L6-30P Power) 3.3' / 1 m (L6-30R Power) 3.3' / 1 m (Management) 3' / 0.91 m (Conduit)
- Enclosure Construction
- Steel
- Form Factor
- Rack / Tower
- Rack Height
- 2 RU
- Operating Relative Humidity
- 0 to 90%
- Operating Temperature
- 32 to 104°F / 0 to 40°C
- Certifications
- RoHS UL 1778 5th Edition
- Dimensions
- 17.0 x 3.4 x 4.9" / 433.0 x 86.5 x 125.0 mm
- Weight
- 8.8 lb / 4 kg
- Warranty
- Limited 3-Year Warranty
- Compatibility
- OL5KRTHD OL6KRTHD
- Input
- Terminal Block to UPS Input Terminal Block to UPS Output Terminal Block to Utility Power
- Input Voltage Range
- 200 to 240 VAC
- Maximum Input Current
- 63 A
- Nominal Output Voltage
- 208 VAC
- Outlets
- 1 x NEMA L6-20R 1 x NEMA L6-30R 1 x Hardwire Terminal Block
- Cord Length
- 3.3' / 1 m (L6-30P Power) 3.3' / 1 m (L6-30R Power) 3.3' / 1 m (Management) 3' / 0.91 m (Conduit)
- Enclosure Construction
- Steel
- Form Factor
- Rack / Tower
- Rack Height
- 2 RU
- Operating Relative Humidity
- 0 to 90%
- Operating Temperature
- 32 to 104°F / 0 to 40°C
- Certifications
- RoHS UL 1778 5th Edition
- Dimensions
- 17.0 x 3.4 x 4.9" / 433.0 x 86.5 x 125.0 mm
- Weight
- 8.8 lb / 4 kg
- Warranty
- Limited 3-Year Warranty
Reviews
No reviews yet.
Write a review
Reviews are accepted from verified buyers.