1 / 3
$249.95
In stock
Free Standard shipping
Typically arrives in 4 business days
Quantity
Key specs
- Power Consumption
- 5.3 DCV
- Dimensions
- 7.9 x 3.0 x 1.7" / 20.0 x 7.6 x 4.2 cm
- Weight
- 1.3 lb / 0.6 kg
- Energy PDU Connections
- 4
- Connectors
- Energy sensor: 4 x RJ-45 female Environment sensor: 4 x RJ-11 female Power: 1 x DC Jack LAN: 1 x RJ-45 female
- Port Selection
- Pushbutton
Overview
The EC1000 Energy Box from Aten is designed to monitor environmental conditions using its four energy sensor ports and its four environment sensor ports. The four energy sensor ports can connect to four Energy PDU modules, and the four environment sensor ports can connect to external sensors for providing measured readings of temperature, humidity, and differential pressure from separate areas of a data room. The box can monitor and display power and environmental data on site or remotely for quick viewing and easy maintenance.
The EC1000 Energy Box is a standalone unit with Over IP monitoring controlled by Web GUI or Aten's eco Sensors software. It features real-time status, systems logs, threshold alerts, and event notifications. The minimum and maximum condition thresholds can be customized, and the remote monitoring is securely accessed with 128 bit SSL encryption and customizable account policies. The remote authentication supports RADIUS, HTTP, HTTPS, SNMPv1, SNMPv2, and SNMPv3. Event notifications can be monitored with Syslog/SMTP/SNMP trap and audible alarms for real-time local and remote alerts. Space saving 1U rack mounting, with front and rear mounting 4 RJ-45 energy sensor ports monitor four Energy PDU currents 4 RJ-11 environment sensor ports monitor temperature, humidity, and differential pressure 3 digit 7 segment front panel LED displays current, sensor, and IP address information Management through eco Sensors energy management software or a 3rd party SNMP manager Supports name assignment for individual Energy PDUs 128 line event log
The EC1000 Energy Box is a standalone unit with Over IP monitoring controlled by Web GUI or Aten's eco Sensors software. It features real-time status, systems logs, threshold alerts, and event notifications. The minimum and maximum condition thresholds can be customized, and the remote monitoring is securely accessed with 128 bit SSL encryption and customizable account policies. The remote authentication supports RADIUS, HTTP, HTTPS, SNMPv1, SNMPv2, and SNMPv3. Event notifications can be monitored with Syslog/SMTP/SNMP trap and audible alarms for real-time local and remote alerts. Space saving 1U rack mounting, with front and rear mounting 4 RJ-45 energy sensor ports monitor four Energy PDU currents 4 RJ-11 environment sensor ports monitor temperature, humidity, and differential pressure 3 digit 7 segment front panel LED displays current, sensor, and IP address information Management through eco Sensors energy management software or a 3rd party SNMP manager Supports name assignment for individual Energy PDUs 128 line event log
Specifications
2 groups · 14 specs
- Energy PDU Connections
- 4
- Connectors
- Energy sensor: 4 x RJ-45 female Environment sensor: 4 x RJ-11 female Power: 1 x DC Jack LAN: 1 x RJ-45 female
- Port Selection
- Pushbutton
- Buttons or Switches
- Reset: 1 x semi-recessed pushbutton Selection: 1 x selection pushbutton
- LED Indicators
- 4 x PDU status 4 x sensor status 3 x energy/environment/IP Selection: 1 digit, 7-segment Current/sensor/IP address: 3 digit, 7-segment 1 x Power 1 x LAN 10 M/100 Mbps 1 x LAN link
- Monitoring Range
- 100 to 240 V, 50 to 60 Hz, 0 to 32 A (per port) LED display resolution: 0.1 A Precision: ±0.1 A @ 0 ~ 1 A, ±1% > 1 A
- Power Consumption
- 5.3 DCV
- Operating Temperature
- 32 to 122°F / 0 to 50°C Humidity: 0-80% RH, non-condensing
- Storage Temperature
- -4 to 140°F / -20 to 60°C Humidity: 0-80% RH, non-condensing
- Compatibility
- Aten PE1216, PE1324
- Housing
- Metal
- Dimensions
- 7.9 x 3.0 x 1.7" / 20.0 x 7.6 x 4.2 cm
- Weight
- 1.3 lb / 0.6 kg
- Energy PDU Connections
- 4
- Connectors
- Energy sensor: 4 x RJ-45 female Environment sensor: 4 x RJ-11 female Power: 1 x DC Jack LAN: 1 x RJ-45 female
- Port Selection
- Pushbutton
- Buttons or Switches
- Reset: 1 x semi-recessed pushbutton Selection: 1 x selection pushbutton
- LED Indicators
- 4 x PDU status 4 x sensor status 3 x energy/environment/IP Selection: 1 digit, 7-segment Current/sensor/IP address: 3 digit, 7-segment 1 x Power 1 x LAN 10 M/100 Mbps 1 x LAN link
- Monitoring Range
- 100 to 240 V, 50 to 60 Hz, 0 to 32 A (per port) LED display resolution: 0.1 A Precision: ±0.1 A @ 0 ~ 1 A, ±1% > 1 A
- Power Consumption
- 5.3 DCV
- Operating Temperature
- 32 to 122°F / 0 to 50°C Humidity: 0-80% RH, non-condensing
- Storage Temperature
- -4 to 140°F / -20 to 60°C Humidity: 0-80% RH, non-condensing
- Compatibility
- Aten PE1216, PE1324
- Housing
- Metal
- Dimensions
- 7.9 x 3.0 x 1.7" / 20.0 x 7.6 x 4.2 cm
- Weight
- 1.3 lb / 0.6 kg
- Warranty
- Available
Reviews
No reviews yet.
Write a review
Reviews are accepted from verified buyers.