Key specs
- Output Power
- 36 W
- Dimensions
- 3.4 x 1.9 x 1.2" (8.6 x 4.8 x 3.1 cm)
- Weight
- 0.4 lb (0.1 kg)
- Input Voltage
- Universal 100 to 240 VAC @ 47 to 63 Hz
- Inrush Current
- 50 A maximum @ any input range
- Cold Start
- 77°F (25°C) @ full load
Overview
The VI0014 12 VDC Power Adapter from VIGITRON is used to power analog and IP CCTV products. It comes equipped with a 2-pin standard IAC power plug that accepts 100 to 240 VAC input. This power adapter protects the connected device from over voltage, short circuit, and over current faults.
Features
Universal AC input / full range 100 to 240 VAC High efficiency and low operation temperature Soft-start current can reduce the AC input impact efficiency Low leakage current Provides short circuit, overload, and over voltage protection Fully enclosed plastic case 100% full-load burning test Installed with EMI filter Class II powerApplications
CCTV equipment Networking equipment Powering transmission equipmentSpecifications
6 groups · 20 specs
- Input Voltage
- Universal 100 to 240 VAC @ 47 to 63 Hz
- Inrush Current
- 50 A maximum @ any input range
- Cold Start
- 77°F (25°C) @ full load
- Output Voltage
- Voltage 12 VDC ± 5% @ 3 A
- Output Power
- 36 W
- Ripple & Noise (max)
- 120 mV @ full load with 20 mHz bandwidth
- Output
- Striped Wired
- Efficiency
- Average: >=81% @ 115 VAC and max load
- Protection
- OVP (Over Voltage Protection) OCP (Over Current Protection) SCP (Short Circuit Protection) Automatic recovery after fault is removed
- Input Voltage
- Universal 100 to 240 VAC @ 47 to 63 Hz
- Inrush Current
- 50 A maximum @ any input range
- Cold Start
- 77°F (25°C) @ full load
- Output Voltage
- Voltage 12 VDC ± 5% @ 3 A
- Output Power
- 36 W
- Ripple & Noise (max)
- 120 mV @ full load with 20 mHz bandwidth
- Output
- Striped Wired
- Efficiency
- Average: >=81% @ 115 VAC and max load
- Protection
- OVP (Over Voltage Protection) OCP (Over Current Protection) SCP (Short Circuit Protection) Automatic recovery after fault is removed
- Certification
- UL, FCC, CE
- Electromagnetic Compatibility Directive
- Immunity EMC Directive 2004/108/EC (EN55022 / EN55024)
- Relative Humidity
- Operating: 20 to 80% Storage: 10 to 90%
- Temperature
- Operating: 32 to 140°F (0 to 60°C) Storage: -4 to 176°F (-20 to 80°C)
- Cooling
- Natural air, no fan required
- Current
- 3 A maximum @ 115/230 input range
- Cable Length
- 70" (178 cm)
- Dimensions
- 3.4 x 1.9 x 1.2" (8.6 x 4.8 x 3.1 cm)
- Weight
- 0.4 lb (0.1 kg)
- Box Dimensions (LxWxH)
- 5.2 x 2.9 x 2.3"
- Package Weight
- 0.47 lb