1 / 2
$318.29
In stock
Free Standard shipping
Typically arrives in 4 business days
Quantity
Key specs
- Power Requirement
- 24 VDC @ 50 mA, Ground-referenced
- Mounting
- Mounts in standard US electrical box
- Dimensions
- 4.11 x 1.31 x 0.98" (10.44 x 3.33 x 2.49 cm)
- Weight
- Not specified by manufacturer
- Level Control
- Optical rotary encoder
- Rotary Encoder
- 5 Rotations (slow rotation, no acceleration) 3 Rotations (medium rotation, with acceleration) 1 Rotation (fast rotation counterclockwise)
Overview
The black DB-RLC10 Remote Level Control from RDL is a rotary remote level control that provides user adjustment at a single or multiple locations. This control is designed to fit any standard single-gang electrical box. The optical encoder technology allows continuous knob rotation with a comfortable adjustment rate and long-term, trouble-free, and noise-free operation. The control directly connects to any RDL, VCA, and OEM equipment with 0 to 10 VDC ramp inputs.
The DB-RLC10 may be connected to a ramp-controlled VCA using a single-pair shielded audio cable or unshielded cable. A rear-panel switch configures the control as the MASTER. The MASTER mode causes this control to drive the 0 to 10 VDC ramp output and to monitor its pulse terminals in case any other -RLC10 controls are connected.
As many as nine additional -RLC10 controls may be wired in parallel with the MASTER control using UTP cable (CAT5, CAT6, or equivalent). The rear-panel MODE switch on each additional remote control is set to SLAVE mode. Operation is the same for a single control, or for each control connected in a multiple control point installation. The 0 to 10 VDC ramp voltage is incremented up or down when the front-panel knob is rotated. Acceleration is provided so the rate of change is faster when the knob is rotated more rapidly, yielding a responsive feel and rapid elimination of acoustic feedback. The LED ring display encircling the control knob operates as a virtual pointer. When the DB-RLC10 is not being adjusted, its display switches to a dim intensity to avoid being a visual distraction. The display returns to a bright intensity during adjustment. In the event of power loss, internal non-volatile memory stores the last level value. When power is restored, the 0 to 10 V output will return to the operating level present when power was lost.
Multiple -RLC10 controls set to the SLAVE MODE may be connected to an RDL RU-VCA2A or RU-VCA6A, utilizing the VCA as the ramp generator. This connection is also possible with OEM equipment accepting open-collector pulses that are compatible with the DB-RLC10 output pulse rate and width. Single or multiple control locations Visual level display of operating level Display is bright during adjustment and dims after adjustment
The DB-RLC10 may be connected to a ramp-controlled VCA using a single-pair shielded audio cable or unshielded cable. A rear-panel switch configures the control as the MASTER. The MASTER mode causes this control to drive the 0 to 10 VDC ramp output and to monitor its pulse terminals in case any other -RLC10 controls are connected.
As many as nine additional -RLC10 controls may be wired in parallel with the MASTER control using UTP cable (CAT5, CAT6, or equivalent). The rear-panel MODE switch on each additional remote control is set to SLAVE mode. Operation is the same for a single control, or for each control connected in a multiple control point installation. The 0 to 10 VDC ramp voltage is incremented up or down when the front-panel knob is rotated. Acceleration is provided so the rate of change is faster when the knob is rotated more rapidly, yielding a responsive feel and rapid elimination of acoustic feedback. The LED ring display encircling the control knob operates as a virtual pointer. When the DB-RLC10 is not being adjusted, its display switches to a dim intensity to avoid being a visual distraction. The display returns to a bright intensity during adjustment. In the event of power loss, internal non-volatile memory stores the last level value. When power is restored, the 0 to 10 V output will return to the operating level present when power was lost.
Multiple -RLC10 controls set to the SLAVE MODE may be connected to an RDL RU-VCA2A or RU-VCA6A, utilizing the VCA as the ramp generator. This connection is also possible with OEM equipment accepting open-collector pulses that are compatible with the DB-RLC10 output pulse rate and width. Single or multiple control locations Visual level display of operating level Display is bright during adjustment and dims after adjustment
Specifications
3 groups · 11 specs
- Level Control
- Optical rotary encoder
- Rotary Encoder
- 5 Rotations (slow rotation, no acceleration) 3 Rotations (medium rotation, with acceleration) 1 Rotation (fast rotation counterclockwise)
- Connector
- 1 x 5-position terminal block
- LED Indicators
- 10 x power
- Power Requirement
- 24 VDC @ 50 mA, Ground-referenced
- Mounting
- Mounts in standard US electrical box
- Dimensions
- 4.11 x 1.31 x 0.98" (10.44 x 3.33 x 2.49 cm)
- Weight
- Not specified by manufacturer
- Level Control
- Optical rotary encoder
- Rotary Encoder
- 5 Rotations (slow rotation, no acceleration) 3 Rotations (medium rotation, with acceleration) 1 Rotation (fast rotation counterclockwise)
- Connector
- 1 x 5-position terminal block
- LED Indicators
- 10 x power
- Power Requirement
- 24 VDC @ 50 mA, Ground-referenced
- Mounting
- Mounts in standard US electrical box
- Dimensions
- 4.11 x 1.31 x 0.98" (10.44 x 3.33 x 2.49 cm)
- Weight
- Not specified by manufacturer
- Box Dimensions (LxWxH)
- 4.9 x 4.3 x 2.3"
- Package Weight
- 0.45 lb
- Warranty
- Available
Reviews
No reviews yet.
Write a review
Reviews are accepted from verified buyers.