1 / 3
In stock
Free Standard shipping
Typically arrives in 4 business days
Quantity
Key specs
- Dimensions
- Overall: 12.25 x 17 x 1.75" (31.11 x 43.18 x 4.44 cm) With Rack Ears: 12.25 x 19 x 1.75" (31.11 x 48.26 x 4.44 cm)
- Weight
- 12 lb (5.44 kg)
- Line Voltage
- 120 V, 60 Hz
- Isolated Filter Banks
- 2
- Voltage Regulation
- No
- Outlets
- Total: 9 High Current: 2
Overview
The M4315-PRO Power Management with Control System from Panamax is a rack-mountable, power management system that features Panamax's AVM (Automatic Voltage Monitoring) circuit and Linear Filtering Technology (LiFT) to provide AC protection and purification. The included BlueBOLT-CV1 provides secure, hosted IP system control and monitoring for the M4315-PRO.
Eight fully controllable/programmable outlets via BlueBOLT-CV1 or RS-232C cards
Linear Filtration with four isolated outlet banks
Two front panel programmable reboot buttons
IP control with BlueBOLT-CV1 and RS-232C cards
Volt/amp meter, outlet status, and warning LEDs
Removable rack ears with a full depth metal chassis
Circuit breaker/power switch
12V input triggering
Specifications
5 groups · 22 specs
- Line Voltage
- 120 V, 60 Hz
- Isolated Filter Banks
- 2
- Voltage Regulation
- No
- Outlets
- Total: 9 High Current: 2
- Max Total Current
- 15 A, 1800 W
- Voltage Protection Rating
- UL 1449 3rd Edition (3,000 A): 500 V
- Protection Modes
- L-N, L-G, N-G
- Clamping Characteristics
- Initial Clamping Level: 200 V Peak, 141 V RMS
- Maximum Energy Dissipation
- 2700 J
- Peak Impulse Current
- 135,000 amps
- Circuit
- Catastrophic Surge Circuit: Yes
- Safe Thermal Fusing
- Yes
- Auto Reset
- Auto-resetting Over-voltage shutoff: 134 VAC ± 2 VAC Auto-resetting Under-voltage shutoff: 100 VAC ± 2 VAC
- EMI / RFI Noise Filtration:
- Banks 1, 2, 3: 76 dB, 5-250 kHz Bank 4 and High Current Outlets: 46 dB, 250 kHz-1 Mhz
- Line Voltage
- 120 V, 60 Hz
- Isolated Filter Banks
- 2
- Voltage Regulation
- No
- Outlets
- Total: 9 High Current: 2
- Max Total Current
- 15 A, 1800 W
- Voltage Protection Rating
- UL 1449 3rd Edition (3,000 A): 500 V
- Protection Modes
- L-N, L-G, N-G
- Clamping Characteristics
- Initial Clamping Level: 200 V Peak, 141 V RMS
- Maximum Energy Dissipation
- 2700 J
- Peak Impulse Current
- 135,000 amps
- Circuit
- Catastrophic Surge Circuit: Yes
- Safe Thermal Fusing
- Yes
- Auto Reset
- Auto-resetting Over-voltage shutoff: 134 VAC ± 2 VAC Auto-resetting Under-voltage shutoff: 100 VAC ± 2 VAC
- EMI / RFI Noise Filtration:
- Banks 1, 2, 3: 76 dB, 5-250 kHz Bank 4 and High Current Outlets: 46 dB, 250 kHz-1 Mhz
- LAN
- Clamping Level: 60 ± 5 V Compatibility: 10/100/1000 BASE-T Jacks: RJ-45 Wires Protected: 8 wires
- Telco
- Fuse-less/Auto-resetting: Yes Clamping Level: 260 V Capacitance: Approx. 30 pf Suppression Modes: metallic and longitudinal Connectors: RJ-11 Lines Protected: 2-wire, pins 4 & 5
- COAX
- HD 1080 i/p Ready: Yes Bidirectional: Yes Shielded: Yes Clamping Level: 75 V Frequency Range: 0 MHz-2.2 GHz Insertion Loss: < 0.5 dB Connectors: Female "F", gold plated
- Dimensions
- Overall: 12.25 x 17 x 1.75" (31.11 x 43.18 x 4.44 cm) With Rack Ears: 12.25 x 19 x 1.75" (31.11 x 48.26 x 4.44 cm)
- Weight
- 12 lb (5.44 kg)
- Box Dimensions (LxWxH)
- 21.5 x 20 x 4.5"
- Package Weight
- 16.8 lb
- Warranty
- Available
Reviews
No reviews yet.
Write a review
Reviews are accepted from verified buyers.