Bosch PRA-AD608 8-Channel 600W Amplifier for PRAESENSA Systems (1 RU)
In stock
Free Standard shipping
Typically arrives in 4 business days
- For PA and Emergency Intercom Systems
- Adaptable Power Loading
- Monitor via Network or Front Panel
Key specs
- Number of Amplifier Channels
- 8
- Power Rating per Channel
- 1x 420 W Peak 105 W RMS at 70 V 7x 300 W Peak 75 W RMS at 70/100 V 1x 600 W Peak 150 W RMS at 100 V
- Frequency Response
- 20 Hz to 20 kHz
- Power
- Power Consumption: Sleep: 6 W Snooze: 7.5 W Active, Idle: 36 W Active, Low Power: 50 W Active, RMS: 222 W Power Consumption per Active Port: 0.4 W
- AC Power Connector
- 1x Block
- Rackmount Size
- 1 U
Overview
It works well in centralized system topologies, but also supports decentralized topologies due to its OMNEO IP-network connection. OMNEO is a high-quality digital audio interface protocol, compatible with Dante and AES67, with an audio sample rate of 48 kHz and 24-bit sample size. The output power of each channel automatically adapts to its connected loudspeaker load and is only limited by the total power budget of the unit. This flexibility and integration of a spare amplifier channel make it possible to utilize the available power effectively and use less amplifiers for the same loudspeaker load compared to using traditional amplifiers..
Efficiency
- Transformerless galvanically isolated, 70/100V outputs for a maximum total load of 600W
- Flexible partitioning of available output power across all amplifier channels reduces the amount of required amplifier power in the system
- Additional space-saving integrated and independent spare channel (maximum 600W) for fail-safe redundancy
- Class-D amplifier channels with two-level power lines, for high-efficiency and heat dissipation
Flexibility
- A/B outputs on every amplifier channel to support redundant loudspeaker wiring topologies. Both outputs are individually supervised and disabled in case of a fault
- Class-A loop wiring is possible between the A and B loudspeaker outputs
- Dedicated connection facility for an end-of-line device to supervise the complete loop, including the B output connection
- Load-independent frequency response—amplifier channels can be used with any loudspeaker load up to the maximum, without any change in audio quality
Sound and Network
- Audio-over-IP using OMNEO high-quality digital audio interface is compatible with Dante and AES67, with an audio sample rate of 48 kHz with 24-bit sample size
- Large signal-to-noise ratio, wide audio bandwidth, and very low distortion and crosstalk
- Digital signal processing on all amplifier channels, including equalization, limiting, and delay, to optimize and tailor the sound in each loudspeaker zone
Supervision
- Supervision of amplifier operation and all of its connections—faults are reported to the system controller and logged
- Loudspeaker line integrity supervision without interruption of audio is acheived using end-of-line devices (separately available) for best reliability
- Network-link supervision via GUI/PRAESENSA system
Fault Tolerance
- Dual OMNEO network connections, supporting Rapid Spanning Tree Protocol (RSTP), for loop-through connections to adjacent devices
- Dual 48 VDC inputs with polarity reversal protection and full power DC/DC converter, operating in tandem for redundancy
- Fully independent amplifier channels; the integrated additional spare channel automatically replaces a failing channel, with due regard to the processing settings
- All amp channels support two independent loudspeaker groups, A and B, enabling redundant loudspeaker wiring topologies
- Backup analog audio lifeline input driving the spare amp channel serves all connected loudspeaker zones to protect from failure of both network connections or the amplifier network interface
Specifications
7 groups · 32 specs
- Item Type
- Distribution Amplifier
- Number of Mixer Inputs
- 1
- Number of Distribution Outputs
- 8
- Number of Amplifier Channels
- 8
- Load Impedance/Voltage Support
- 70 V (8.3 Ohms Nominal) 100 V (16.7 Ohms Nominal)
- Power Rating per Channel
- 1x 420 W Peak 105 W RMS at 70 V 7x 300 W Peak 75 W RMS at 70/100 V 1x 600 W Peak 150 W RMS at 100 V
- Amplifier Class
- Class-D
- Item Type
- Distribution Amplifier
- Number of Mixer Inputs
- 1
- Number of Distribution Outputs
- 8
- Number of Amplifier Channels
- 8
- Load Impedance/Voltage Support
- 70 V (8.3 Ohms Nominal) 100 V (16.7 Ohms Nominal)
- Power Rating per Channel
- 1x 420 W Peak 105 W RMS at 70 V 7x 300 W Peak 75 W RMS at 70/100 V 1x 600 W Peak 150 W RMS at 100 V
- Amplifier Class
- Class-D
- Protections
- AC Coupling, AC Fuse, Overload, Overvoltage, Power Supply, Short Circuit, Thermal
- Frequency Response
- 20 Hz to 20 kHz
- SNR/Noise
- > 90 dBA SNR
- Crosstalk
- < -84 dB
- Load Capacity
- Loudspeaker Load, Both Modes, All Channels (Maximum): 600 W Minimum Output Load Impedance, 100 V, All Channels: 16.70 Ohms Minimum Output Load Impedance, 70 V, All Channels: 8.3 Ohms Maximum Cable Capacitance, Both Modes, All Channels: 200 nF
- Audio
- Full to No Load Regulation (dB) (20 Hz to 20.000 Hz): < 0.2 dB Frequency Response (-3 dB) (Hz) (RMS, +0.5): 20 Hz to 20,000 Hz THD+N: (RMS, 20 Hz to 20.000 Hz): < 0.50% THD+N: (6 dB below RMS, 20 Hz to 20 Hz): < 0.1% Intermodulation Distortion (19/20 kHz) (6 dB below RMS, 1:1): < 0.10 % Minimum SNR (100 V, 20 Hz to 20.000 Hz): 110 dBA Minimum SNR (70 V, 20 Hz to 20.000 Hz): 107 dBA Crosstalk (100 Hz to 20.000 Hz): < -84 dBA
- Power
- Power Consumption: Sleep: 6 W Snooze: 7.5 W Active, Idle: 36 W Active, Low Power: 50 W Active, RMS: 222 W Power Consumption per Active Port: 0.4 W
- Network
- Network Interface: Link Presence Ethernet type: 100BASE-TX; 1000BASE-T Ethernet Protocol: TCP/IP Redundancy: RSTP Control/Audio Protocol: OMNEO Latency of Network Audio: 10 ms Audio Encryption: AES 128 Security: TLS Mean Time Between Failures (calculated according to Telcordia SR‑332 Issue 3): 250000h
- Protection
- End-of-line Detection Mode: Pilot Tone Supervision, 25.5 kHz, 3 VRMS Power supply Input A/B Undervoltage Ground Short Detection (loudspeaker lines) < 50 Kilohms Amplifier Channel Redundancy Switching: Internal Spare Channel Amplifier Channel Load: Short Circuit Loudspeaker Line Redundancy Switching: A/B group, Class A Loop Controller Continuity: Watchdog
- Certifications
- Europe: EN 54‑16 (0560-CPR-182190000) International: ISO 7240‑16 Maritime Applications: DNV GL Type Approval Mass Notifications Systems: UL 2572 Emergency Standard Certifications: Control Units and Accessories for Fire Alarm Systems: UL 864 Emergency Standard Compliance: Europe: EN 50849 UK: BS 5839-8
- Standards
- Safety: EN/IEC/CSA/UL 62368‑1 Immunity: EN 55035 EN 50130‑4 Emissions: EN 55032 EN 61000‑6‑3 ICES‑003 FCC‑47 part 15B class A EN 62479 Environment: EN/IEC 63000 Railway Applications: EN 50121‑4
- DSP
- No
- Analog Audio I/O
- 1x Proprietary 4-Pin Balanced Input 8x Push Terminal Balanced Output
- Digital Audio I/O
- No
- Network I/O
- 2x RJ45
- USB I/O
- No
- Wireless
- No
- AC Power Connector
- 1x Block
- Display
- Multi-Segment LED Meters
- Rackmount Size
- 1 U
- Cooling
- Fan
- Operating Conditions
- 23 to 122°F / -5 to 50°C at 5 to 95% Humidity (Recommended)
- Dimensions
- 19 x 15.7 x 1.7" / 483 x 400 x 44 mm
- Weight
- 19.4 lb / 8.8 kg
- Warranty
- Available
Reviews
No reviews yet.
Write a review
Reviews are accepted from verified buyers.