Axis Communications T92E20 Outdoor Housing
SKU 857415MPN 0433-001UPC 7331021034211
1 / 4
$379.00
In stock
Free Standard shipping
Typically arrives in 4 business days
Quantity
Key specs
- Power
- Power over Ethernet (PoE) IEEE 802.3af or High Power over Ethernet (High PoE)
- Weight
- 5.5 lb (2.5 kg)
- Supported Cameras
- AXIS M1113, AXIS M1114, AXIS P1343, AXIS P1344, AXIS P1346, AXIS P1347, and AXIS Q1755
- Casing
- Aluminum casing, polycarbonate sunshield and cable cover IP66- and NEMA 4X-rated, IK10 impact-resistant aluminum enclosure
- Environment
- Indoor/outdoor
- Axis Q1755
- PoE IEEE 802.3af: -22 to 113ºF (-30 to 45ºC) High PoE IEEE 802.3at: -40 to 113ºF (-40 to 45ºC) Humidity 15 - 100% RH (condensing)
Overview
The Axis Communications T92E20 Outdoor Housing is designed for use with the Axis M11, P13, and Q17 series Outdoor Network Cameras. The most unique feature of this housing is its dual shell that helps maintain the optimum internal temperature in extreme weather conditions. The housing's internal shell stores heat in cold environments, while the built-in fan transfers excess hot air to the outer chassis for efficient cooling. Furthermore, the polycarbonate sunshield and cable cover are designed to withstand adverse weather conditions.
The IP66- and NEMA 4X-rated housing protects your camera against the ingress of dust, windblown dust, rain, high pressure water jets from any direction, hose-directed water, and damage from external ice formation. In addition, IK10-rated housing can withstand high-impact force, shock, and vibration, making it suitable for use in high-risk environments Outdoor housing box for Axis M1113, M1114, P1343, P1344, P1346, P1347, and Q1755 Network Camera Dual shell technology - An internal shell stores the heat in cold environments, and the built-in fan provides ventilation in high temperatures IP66 and NEMA Type 4X-rating protects against dust, windblown dust, rain, high pressure water jets from any direction, hose-directed water, and damage from external ice formation Easy and quick installation using either power over Ethernet(POE) or high power over Ethernet connection The casing is made from durable and lightweight aluminum IK10-rated, this vandal-proof metal base can withstand high-impact force, shock, and vibration making it suitable for use in high-risk environments Arctic Temperature Control functionality ensures that the cameras can start up even at -40°F (-40°C) following a power failure Polycarbonate sunshield protects the unit from direct sunlight Network cable located in the wall mount for enhanced vandalism protection VT wall bracket included for mounting installations
The IP66- and NEMA 4X-rated housing protects your camera against the ingress of dust, windblown dust, rain, high pressure water jets from any direction, hose-directed water, and damage from external ice formation. In addition, IK10-rated housing can withstand high-impact force, shock, and vibration, making it suitable for use in high-risk environments Outdoor housing box for Axis M1113, M1114, P1343, P1344, P1346, P1347, and Q1755 Network Camera Dual shell technology - An internal shell stores the heat in cold environments, and the built-in fan provides ventilation in high temperatures IP66 and NEMA Type 4X-rating protects against dust, windblown dust, rain, high pressure water jets from any direction, hose-directed water, and damage from external ice formation Easy and quick installation using either power over Ethernet(POE) or high power over Ethernet connection The casing is made from durable and lightweight aluminum IK10-rated, this vandal-proof metal base can withstand high-impact force, shock, and vibration making it suitable for use in high-risk environments Arctic Temperature Control functionality ensures that the cameras can start up even at -40°F (-40°C) following a power failure Polycarbonate sunshield protects the unit from direct sunlight Network cable located in the wall mount for enhanced vandalism protection VT wall bracket included for mounting installations
Specifications
3 groups · 17 specs
- Supported Cameras
- AXIS M1113, AXIS M1114, AXIS P1343, AXIS P1344, AXIS P1346, AXIS P1347, and AXIS Q1755
- Casing
- Aluminum casing, polycarbonate sunshield and cable cover IP66- and NEMA 4X-rated, IK10 impact-resistant aluminum enclosure
- Power
- Power over Ethernet (PoE) IEEE 802.3af or High Power over Ethernet (High PoE)
- Environment
- Indoor/outdoor
- Axis Q1755
- PoE IEEE 802.3af: -22 to 113ºF (-30 to 45ºC) High PoE IEEE 802.3at: -40 to 113ºF (-40 to 45ºC) Humidity 15 - 100% RH (condensing)
- Axis P1343
- PoE IEEE 802.3af: -22 to 122ºF (-30 to 50ºC) High PoE IEEE 802.3at: -40 to 122ºF (-40 to 50ºC) Humidity 15 - 100% RH (condensing)
- Axis P1344
- PoE IEEE 802.3af: -22 to 122ºF (-30 to 50ºC) High PoE IEEE 802.3at: -40 to 122ºF (-40 to 50ºC) Humidity 15 - 100% RH (condensing)
- Axis P1346
- PoE IEEE 802.3af: -22 to 122ºF (-30 to 50ºC) High PoE IEEE 802.3at: -40 to 122ºF (-40 to 50ºC) Humidity 15 - 100% RH (condensing)
- Axis P1347
- PoE IEEE 802.3af: -22 to 122ºF (-30 to 50ºC) High PoE IEEE 802.3at: -40 to 122ºF (-40 to 50ºC) Humidity 15 - 100% RH (condensing)
- Axis M1113
- PoE IEEE 802.3af: -22 to 122ºF (-30 to 50ºC) High PoE IEEE 802.3at: -31 to 122ºF (-35 to 50ºC) Humidity 15 - 100% RH (condensing)
- Axis M1114
- PoE IEEE 802.3af: -22 to 122ºF (-30 to 50ºC) High PoE IEEE 802.3at: --31 to 122ºF (-35 to 50ºC) Humidity 15 - 100% RH (condensing)
- Protection Rating
- IEC 60529 IP66, NEMA 250 Type 4X, IEC 62262 IK10
- Approvals
- EN 55022 Class B, EN 61000-3-2, EN 61000-3-3, EN 55024, EN 61000-6-1, EN 61000-6-2, EN 60950-22, IEC 60068-2-6, IEC 60068-2-27, FCC Part 15, Subpart B, Class B, VCCI, Class B ITE, C-tick AS/NZS CISPR 22, ICES-003, and Class B
- Weight
- 5.5 lb (2.5 kg)
- Supported Cameras
- AXIS M1113, AXIS M1114, AXIS P1343, AXIS P1344, AXIS P1346, AXIS P1347, and AXIS Q1755
- Casing
- Aluminum casing, polycarbonate sunshield and cable cover IP66- and NEMA 4X-rated, IK10 impact-resistant aluminum enclosure
- Power
- Power over Ethernet (PoE) IEEE 802.3af or High Power over Ethernet (High PoE)
- Environment
- Indoor/outdoor
- Axis Q1755
- PoE IEEE 802.3af: -22 to 113ºF (-30 to 45ºC) High PoE IEEE 802.3at: -40 to 113ºF (-40 to 45ºC) Humidity 15 - 100% RH (condensing)
- Axis P1343
- PoE IEEE 802.3af: -22 to 122ºF (-30 to 50ºC) High PoE IEEE 802.3at: -40 to 122ºF (-40 to 50ºC) Humidity 15 - 100% RH (condensing)
- Axis P1344
- PoE IEEE 802.3af: -22 to 122ºF (-30 to 50ºC) High PoE IEEE 802.3at: -40 to 122ºF (-40 to 50ºC) Humidity 15 - 100% RH (condensing)
- Axis P1346
- PoE IEEE 802.3af: -22 to 122ºF (-30 to 50ºC) High PoE IEEE 802.3at: -40 to 122ºF (-40 to 50ºC) Humidity 15 - 100% RH (condensing)
- Axis P1347
- PoE IEEE 802.3af: -22 to 122ºF (-30 to 50ºC) High PoE IEEE 802.3at: -40 to 122ºF (-40 to 50ºC) Humidity 15 - 100% RH (condensing)
- Axis M1113
- PoE IEEE 802.3af: -22 to 122ºF (-30 to 50ºC) High PoE IEEE 802.3at: -31 to 122ºF (-35 to 50ºC) Humidity 15 - 100% RH (condensing)
- Axis M1114
- PoE IEEE 802.3af: -22 to 122ºF (-30 to 50ºC) High PoE IEEE 802.3at: --31 to 122ºF (-35 to 50ºC) Humidity 15 - 100% RH (condensing)
- Protection Rating
- IEC 60529 IP66, NEMA 250 Type 4X, IEC 62262 IK10
- Approvals
- EN 55022 Class B, EN 61000-3-2, EN 61000-3-3, EN 55024, EN 61000-6-1, EN 61000-6-2, EN 60950-22, IEC 60068-2-6, IEC 60068-2-27, FCC Part 15, Subpart B, Class B, VCCI, Class B ITE, C-tick AS/NZS CISPR 22, ICES-003, and Class B
- Weight
- 5.5 lb (2.5 kg)
- Box Dimensions (LxWxH)
- 22.5 x 9.7 x 8.2"
- Package Weight
- 10.6 lb
- Warranty
- Available
Reviews
No reviews yet.
Write a review
Reviews are accepted from verified buyers.











