Key specs
- Channels
- 2
- Maximum Output Power
- Max Output Power Per Channel, Low Impedance Output, All Channels Driven 2 Ohms: 1500 W, 4 Ohms: 1500 W, 8 Ohms: 1250 W Low Impedance Output, Bridge Mode, All Channels Driven 4 Ohms: 3000 W 8 Ohms: 3000 W 70 V, 100 V Output, All Channels Driven 70 V (per channel): 1500 W 100 V (per channel): 1250 W
- Power Draw
- Total Power Draw All Channels Driven Sleep Mode: <1 W Standby Mode: 40 W Idle (no signal): 55 W
- Frequency Response
- 20 Hz to 20 kHz, +/-0.05 dB
- Power Requirements
- @ 50/60 Hz Nominal (Automatic Sensing SMPS): 120 to 240 VAC Operating Range: 70 to 135 VAC to 140 to 270 VAC Minimum Power-Up: 85 to 170 VAC Power Cable Connector: 20 A powerCON
- Dimensions
- 19 x 3.5 x 16.84 (483 x 89 x 428 mm)
Overview
The multi-mode amplifier features an automatic but defeatable sleep mode consuming <1W, and instant standby mode controlled by contact closure or software. A switch mode power supply can auto-detect 120 or 240 VAC mains, and a Neutrik powerCON is used for the AC cord. Each channel features a selectable output mode of Low Z, 70V, or 100V, an 80 Hz high-pass filter, input limiter, and input gain settings of 26 dB, 32 dB, 38 dB, or 1.4V. Each channel comes with a remote DC level control.
The amplifier comes with Neutrik XLR/TRS combo jack and Euroblock input connectors and Neutrik speakON output connectors. The unit features a front panel power switch and level controls that can be disabled. The LEDs indicate Protect, Sleep, Disabled, Com, and Bridge mode status, as well as Temperature, Output Current, Output Signal, and Clipping/Mute status per channel. In addition, the power amplifier features an Ethernet control with a real-time clock for event scheduling.
The power amplifier is equipped with serial data remote control, aux preamp outputs, preset control, and fault condition logic outputs. It also features a temperature dependent variable speed forced-air cooling. In addition, the amplifier can be mounted on a standard 19” rack. Ethernet control using Protea NE software Serial data control by Ashly programmable remotes or third party controllers Aux preamp outputs, instant standby mode, preset recall, fault condition logic outputs, optional AES3 digital audio capability, and Cobranet Real-time clock with event scheduler Assign automatic execution of selected functions and tasks Event scheduler is programmed using PneS software and stored in the amplifier Ashly remote control via iPad app for custom design of secure wireless control over a network Features a switch-mode power supply that automatically detects 120 VAC or 240 VAC operation Selectable outputs on each channel allow you to choose the desired output mode Set the DIP-switch configuration for low impedance (2, 4, and 8 Ohms), or constant voltage (70V or 100V) Ashly EMS (Energy Management System) provides an automatic sleep-mode drawing less than 1W (defeatable) Multiple internal power supplies provide increased channel separation and reliability Selectable 80 Hz hi-pass filter, limiter, and input gain per channel via rear panel Remote DC level control per channel Extensive protection circuitry and continuously variable cooling fans Ethernet port for software control and monitoring of amplifier functions with front panel COM activity LED Serial data port available for optional Ashly WR-5 and RD-8C programmable remote controls (optional RS-232 converter INA-1 available for third party controllers) Instant standby mode results in 30% reduction in idle power consumption that is triggered by contact closure, software control, or event scheduler Preset recall via contact closure, software control, remote control, or event scheduler Programmable power-on delay Aux preamp line outputs for driving other amplifiers Assignable fault condition logic outputs Neutrik Combo XLR - 1/4" TRS jack plus Euroblock input connectors Neutrik speakON twist locking loudspeaker connectors Neutrik powerCON detachable AC mains connector
Specifications
2 groups · 32 specs
- Channels
- 2
- Maximum Output Power
- Max Output Power Per Channel, Low Impedance Output, All Channels Driven 2 Ohms: 1500 W, 4 Ohms: 1500 W, 8 Ohms: 1250 W Low Impedance Output, Bridge Mode, All Channels Driven 4 Ohms: 3000 W 8 Ohms: 3000 W 70 V, 100 V Output, All Channels Driven 70 V (per channel): 1500 W 100 V (per channel): 1250 W
- Power Draw
- Total Power Draw All Channels Driven Sleep Mode: <1 W Standby Mode: 40 W Idle (no signal): 55 W
- Current Draw
- Current Draw 120 VAC Mains (divide in half for 240V) Sleep Mode: 0.1 A Standby Mode: 0.7 A Idle (no signal): 1 A Maximum Current Draw All Channels Driven, Divide by 2 for 240 VAC 1/8 Maximum Power @ 2 Ohms: 8 A
- Dissipation
- Thermal Dissipation BTU/hr, Total for All Channels Driven Sleep Mode: <3.4 Standby Mode: 136 BTU/hr Idle (no signal): 187 BTU/hr 1/8 Maximum Power @ 2 Ohms: 850 BTU/hr
- Voltage Gain
- Selectable at 26 dB, 32 dB, 38 dB, or 1.4 V
- Damping Factor
- >250 (8 Ohms load <1 kHz)
- High Pass Filter
- Input: 80 Hz 2nd order
- Distortion
- SMPTE, typical: <0.5% THD-N, typical: <0.5% (8 Ohms, 10 dB below rated power, 20 Hz to 20 kHz)
- Channel Separation
- -75 dB (dB from full output, 1 kHz)
- Signal-to-Noise Ratio
- 20 Hz to 20 kHz, Unweighted: >111 dB
- Frequency Response
- 20 Hz to 20 kHz, +/-0.05 dB
- Input Connector
- Balanced: Euroblock 3.5 mm, 1/4" TRS and XLR combo jack
- Input Impedance
- 10 kOhms
- Maximum Input Level
- +21 dBu
- Output Connector
- Speaker: Neutrik speakON AUX: Balanced Euroblock 3.5 mm
- Network
- Control Network: Compatible with standard 100 MB Ethernet
- Aux Output Level
- Maximum: +21 dBu
- Contact Closure
- Remote Standby: Euroblock 3.5 mm, close contact to GND for standby mode Preset Recall: Euroblock 3.5 mm, close contact to GND for preset 1-4 recall
- Supported Data Connections
- Euroblock 3.5 mm - Gnd, +18 V, In, Out
- Logic Output
- Fault Condition: Euroblock 3.5 mm - 4 available
- Level Control
- Remote DC: Euroblock 3.5 mm - Gnd, CV, V+ per input
- Active Attenuators
- Per Channel: Front panel, software, offset link group, and remote Fully Off: Mute
- Amplifier Protection
- Inrush current limitation, temperature monitoring, output over-power protection, mains fuses
- Cooling
- Continuously variable temperature controlled axial fan(s)
- Environmental
- 32 to 113°F (0 to 45°C) (non-condensing)
- Front Panel LED Indicators
- POWER (white): Switch: On, Off, Standby (flashing) PROTECT (red): On (fault condition or shut down), Off SLEEP (blue): On, amplifier is asleep from audio inactivity DISABLE (yellow): On, power switch & front panel attenuators are disabled Per Channel CLIP/MUTE (red): Clip @ 1 dB below full output / Mute SIGNAL (green): -18 dB below rated output CURRENT (green): Proportional to output TEMP (yellow): On dim at 90% max operating temperature, full bright + protect at 100% BRIDGE (green): On, Off
- Power Requirements
- @ 50/60 Hz Nominal (Automatic Sensing SMPS): 120 to 240 VAC Operating Range: 70 to 135 VAC to 140 to 270 VAC Minimum Power-Up: 85 to 170 VAC Power Cable Connector: 20 A powerCON
- Compliance
- cTUVus, CE, FCC, RoHS
- Dimensions
- 19 x 3.5 x 16.84 (483 x 89 x 428 mm)
- Weight
- 22.7 lb (10.3 kg)
- Channels
- 2
- Maximum Output Power
- Max Output Power Per Channel, Low Impedance Output, All Channels Driven 2 Ohms: 1500 W, 4 Ohms: 1500 W, 8 Ohms: 1250 W Low Impedance Output, Bridge Mode, All Channels Driven 4 Ohms: 3000 W 8 Ohms: 3000 W 70 V, 100 V Output, All Channels Driven 70 V (per channel): 1500 W 100 V (per channel): 1250 W
- Power Draw
- Total Power Draw All Channels Driven Sleep Mode: <1 W Standby Mode: 40 W Idle (no signal): 55 W
- Current Draw
- Current Draw 120 VAC Mains (divide in half for 240V) Sleep Mode: 0.1 A Standby Mode: 0.7 A Idle (no signal): 1 A Maximum Current Draw All Channels Driven, Divide by 2 for 240 VAC 1/8 Maximum Power @ 2 Ohms: 8 A
- Dissipation
- Thermal Dissipation BTU/hr, Total for All Channels Driven Sleep Mode: <3.4 Standby Mode: 136 BTU/hr Idle (no signal): 187 BTU/hr 1/8 Maximum Power @ 2 Ohms: 850 BTU/hr
- Voltage Gain
- Selectable at 26 dB, 32 dB, 38 dB, or 1.4 V
- Damping Factor
- >250 (8 Ohms load <1 kHz)
- High Pass Filter
- Input: 80 Hz 2nd order
- Distortion
- SMPTE, typical: <0.5% THD-N, typical: <0.5% (8 Ohms, 10 dB below rated power, 20 Hz to 20 kHz)
- Channel Separation
- -75 dB (dB from full output, 1 kHz)
- Signal-to-Noise Ratio
- 20 Hz to 20 kHz, Unweighted: >111 dB
- Frequency Response
- 20 Hz to 20 kHz, +/-0.05 dB
- Input Connector
- Balanced: Euroblock 3.5 mm, 1/4" TRS and XLR combo jack
- Input Impedance
- 10 kOhms
- Maximum Input Level
- +21 dBu
- Output Connector
- Speaker: Neutrik speakON AUX: Balanced Euroblock 3.5 mm
- Network
- Control Network: Compatible with standard 100 MB Ethernet
- Aux Output Level
- Maximum: +21 dBu
- Contact Closure
- Remote Standby: Euroblock 3.5 mm, close contact to GND for standby mode Preset Recall: Euroblock 3.5 mm, close contact to GND for preset 1-4 recall
- Supported Data Connections
- Euroblock 3.5 mm - Gnd, +18 V, In, Out
- Logic Output
- Fault Condition: Euroblock 3.5 mm - 4 available
- Level Control
- Remote DC: Euroblock 3.5 mm - Gnd, CV, V+ per input
- Active Attenuators
- Per Channel: Front panel, software, offset link group, and remote Fully Off: Mute
- Amplifier Protection
- Inrush current limitation, temperature monitoring, output over-power protection, mains fuses
- Cooling
- Continuously variable temperature controlled axial fan(s)
- Environmental
- 32 to 113°F (0 to 45°C) (non-condensing)
- Front Panel LED Indicators
- POWER (white): Switch: On, Off, Standby (flashing) PROTECT (red): On (fault condition or shut down), Off SLEEP (blue): On, amplifier is asleep from audio inactivity DISABLE (yellow): On, power switch & front panel attenuators are disabled Per Channel CLIP/MUTE (red): Clip @ 1 dB below full output / Mute SIGNAL (green): -18 dB below rated output CURRENT (green): Proportional to output TEMP (yellow): On dim at 90% max operating temperature, full bright + protect at 100% BRIDGE (green): On, Off
- Power Requirements
- @ 50/60 Hz Nominal (Automatic Sensing SMPS): 120 to 240 VAC Operating Range: 70 to 135 VAC to 140 to 270 VAC Minimum Power-Up: 85 to 170 VAC Power Cable Connector: 20 A powerCON
- Compliance
- cTUVus, CE, FCC, RoHS
- Dimensions
- 19 x 3.5 x 16.84 (483 x 89 x 428 mm)
- Weight
- 22.7 lb (10.3 kg)
- Warranty
- Available