- Emergency Power Off (EPO) Support
- Yes
- Input Frequency
- 50/60 Hz ± 3 Hz (Auto Sensing)
- Output Frequency
- 50/60 Hz ± 3 Hz
- Rackmount Size
- 4 U (with Included Hardware)
- Dimensions (W x H x D)
- 7 x 17 x 19" / 178 x 432 x 483 mm
- Weight
- 85.1 lb / 38.6 kg
Overview
The black Smart-UPS X 2000VA Rack / Tower LCD 100-127V from APC provides power to your important computer components in the event of an electrical outage. The Uninterruptible Power Supply (UPS) contains a battery which continues to power computers, monitors and other components if electricity is discontinued from them. The LED status indicator quickly understands the unit and power status with visual indicators. The battery is easy to replace and an audible alarm alerts you of events like power outage and low battery.
Intuitive LCD Interface
Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy-to-use navigation keysHigh Frequency Design
Reduces or eliminates bulky transformers, resulting in lighter units for ease of handlingAuto Recognition of External Batteries
Recognizes when external battery packs are attached and automatically adjusts runtimePredictive Replace Battery Date
Dynamically provides the month and year when battery replacement is recommended to aid in long-term maintenance planningGreen Mode
A patent-pending operating mode bypasses unused electrical components in good power conditions to achieve operating efficiency without sacrificing protectionEnergy Meter
Provides actual kilowatt hours of usage for energy conscious usersOutlet Group Control
Turn on / off, reboot or shut down select outlet groups to save dispatching technicians to remote locations (for UPSs with switched outlet groups)Load Shedding
Turn off select outlet groups in a pre-determined sequence to shed less critical equipment and conserve runtime (UPSs with switched outlet groups)Multiple Switched Outlet Groups
Multiple outlet groups that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load sheddingHigh Online Efficiency
Reduces utility costs, generates less heatSmart-Slot
Customize UPS capabilities with management cardsAutomatic Restart of Loads After UPS Shutdown
Automatically starts up the connected equipment upon the return of utility powerScalable Runtime
Allows additional runtime to be quickly added as neededRack / Tower Convertible
Protects the initial investment in the UPS when migrating from tower to rack-mount environmentSequenced Network Shutdown and Reboot
Customize network shutdown and reboot sequence of connected servers and UPSsAvailability
Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using batteryIntelligent Battery Management
Maximizes battery performance, life and reliability through intelligent precision chargingPower Conditioning
Protects connected loads from surges, spikes, lightning and other power disturbancesTemperature-Compensated Battery Charging
Prolongs battery life by regulating the charge voltage according to battery temperatureAutomatic Restart of Loads After UPS Shutdown
Automatic Self-Test
Periodic battery self-test ensures early detection of a battery that needs to be replacedDisconnected Battery Notification
Warns when a battery is not available to provide backup powerManageability
Network Manageable
Provides remote power management of the UPS over the networkAudible Alarms
Actively let you know if the unit is on battery, if the battery is low or if there is an overload conditionLED Status Indicators
Quickly understand unit and power status with visual indicatorsSerial Connectivity
Provides management of the UPS via a serial portUSB Connectivity
Provides management of the UPS via a USB portServiceability
User-Replaceable Batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries, thereby reducing Mean Time to Repair (MTTR)Hot-Swappable Batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replacedPredictive Failure Notification
Provides early-warning fault analysis, ensuring proactive component replacementResettable Circuit Breakers
Enables a quick recovery from overload eventsBattery Failure Notification
Provides early-warning fault analysis on batteries, enabling timely preventive maintenanceAdaptability
Adjustable Voltage-Transfer Points
Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulationAdjustable Voltage Sensitivity
Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applicationsSafety
Safety Agency Approved
The product has been tested and approved to work safely with the connected service provider equipment and within the specified environmentSpecifications
7 groups · 40 specs
- Total Outlets
- 6x NEMA 5-15R 3x NEMA 5-20R 1x NEMA L5-20R
- Plug Type
- NEMA 5-20P
- Surge Protection
- Yes: 540 Joules
- Maximum Wattage
- 1800 W
- Full-Load Runtime
- 10 Minutes
- Total Outlets
- 6x NEMA 5-15R 3x NEMA 5-20R 1x NEMA L5-20R
- Plug Type
- NEMA 5-20P
- Surge Protection
- Yes: 540 Joules
- Maximum Wattage
- 1800 W
- Full-Load Runtime
- 10 Minutes
- Total Outlets
- 6x NEMA 5-15R 3x NEMA 5-20R 1x NEMA L5-20R
- Plug Type
- NEMA 5-20P
- SmartSlot Interface
- 1
- Data Line Protection
- RJ45
- Communications I/O
- Serial via RJ45 USB via USB-B
- Emergency Power Off (EPO) Support
- Yes
- Noise Filtering
- 0.3%
- Topology
- Line Interactive
- Transfer Time
- 2 to 4 ms
- Surge Protection
- Yes: 540 Joules
- Maximum Wattage
- 1800 W
- Nominal Input Voltage
- 120 VAC
- Input Voltage Adjustable Range
- 70 to 154 VAC
- Input Frequency
- 50/60 Hz ± 3 Hz (Auto Sensing)
- Nominal Output Voltage
- 120 VAC
- Output Frequency
- 50/60 Hz ± 3 Hz
- Voltage Distortion
- <5%
- Load Capacity
- 1920 VA
- Thermal Dissipation
- 203 BTU/Hour
- Waveform
- Sine Wave
- Chemistry
- Lead-Acid
- Full-Load Runtime
- 10 Minutes
- Half-Load Runtime
- 27 Minutes
- Recharge Time
- 3 Hours
- Number of Batteries
- 1
- Operating Conditions
- 32 to 104°F / 0 to 40°C up to 95% Humidity
- Noise Level
- 55 dBA
- Certifications
- REACH, RoHS
- Cable Length
- 7.9' / 2.4 m
- Rackmount Size
- 4 U (with Included Hardware)
- Dimensions (W x H x D)
- 7 x 17 x 19" / 178 x 432 x 483 mm
- Weight
- 85.1 lb / 38.6 kg
- Box Dimensions (LxWxH)
- 25 x 23.2 x 12.5"
- Package Weight
- 97.9 lb
- Warranty
- Available