  • Output: 3000 VA / 2700W
  • Input: 100-275 VAC @ 40-70 Hz
  • 8 x IEC 320 C13 (Battery Backup)
View all features

Key specs

Emergency Power Off (EPO) Support
Yes
Input Frequency
50/60 Hz ± 10 Hz (Auto Sensing)
Output Frequency
50/60 Hz ± 3 Hz
Rackmount Size
2 U (with Non-Included Hardware)
Dimensions (W x H x D)
17 x 3.3 x 25" / 43.2 x 8.5 x 63.5 cm
Weight
69 lb / 31.3 kg

Overview

The Smart-UPS SRT Battery Backup from APC provides high-density, double-conversion, online power protection for servers, voice/data networks, medical labs, and light industrial applications. To meet the demands of business-critical systems, this Smart-UPS can be configured with up to four external battery packs to meet more aggressive runtime demands. Additionally, included PowerChute Network Shutdown management software helps to provide unattended, yet proper shutdowns of network operating systems.

APC has built this Smart-UPS SRT with an output of 3000 VA / 2700W, an input range of 100-275 VAC @ 40-70 Hz, eight IEC 320 C13 outputs, two IEC 320 C19 outputs, two IEC jumper (battery backup) inputs, British BS1363A, IEC-320 C20, and Schuko CEE 7/EU1-16P input connections, a surge energy rating of 340 joules, and a sine waveform. The built-in APCRBC152 battery is a country-specific detachable power cord, removable support feet, and a USB cable. Support is provided by a limited 3-year repair or replace warranty that excludes the battery, as well as a limited 2-year battery warranty.

General Features

UPS Half/Full Loads

Internal Battery - 11.8/4.0 minutes

Remote Accessibility

Network manageable via serial, USB, or Ethernet. Includes Powerchute Network Shutdown Software for convenient monitoring and control, safe operating system shutdown, and energy management capabilities.

Low Operating and Maintenance Costs / Intelligent Battery Management.

Intelligent battery management helps maximize battery performance and life through intelligent, precision temperature compensated charging. Automatic self tests help insure battery reliability and warn customers in advance of battery replacement. Convenient, easy to connect, and hot-swappable battery modules provide battery replacement without powering down.

Keep IT Equipment and Data Protected & Available

Network grade power conditioning helps protect against damaging surges and disruptive noise. The double conversion architecture provides tight voltage regulation, frequency regulation, and zero transfer time to batteries during power events.

Equipment Compatibility

Provides pure sine wave output which is recommended by server manufacturers using active power factor corrected (PFC) power supplies. Safety agency tested and approved means that you can deploy your Smart-UPS with confidence that it meets or exceeds the industry standards.

Battery Failure Notification

Provides early-warning fault analysis on batteries, enabling timely preventive maintenance

ECO Mode

Operating mode that bypasses unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection.

Green Mode

Operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.

LCD Graphics Display

Text and mimic diagrams that display modes of operation, system parameters, and alarms.

Rack/Tower Convertible

Protects the initial investment in the UPS when migrating from tower to rack-mount environment.

Availability

Automatic Internal Bypass

Supplies utility power to the connected loads in the event of a UPS power overload or fault.

Scalable Runtime

Allows additional run time to be quickly added as needed.

Intelligent Battery Management

Maximizes battery performance, life, and reliability through intelligent, precision charging.

Temperature-Compensated Battery Charging

Prolongs battery life by regulating the charge voltage according to battery temperature.

Automatic Restart of Loads After UPS Shutdown

Automatically starts up the connected equipment upon the return of utility power.

Hot-Swappable Batteries

Ensures clean, uninterrupted power to protected equipment while batteries are being replaced.

Manageability

LED Status Indicators

Quickly understand unit and power status with visual indicators.

SmartSlot

Customize UPS capabilities with management cards.

Serial Connectivity

Provides management of the UPS via a serial port.

InfraStruXure Manager Compatible

Enables centralized management via the APC InfraStruXure Manager.

Network Manageable

Provides remote power management of the UPS over the network.

Protection

Safety-Agency Approved

Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

Frequency and Voltage Regulation

Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.

Power Conditioning

Protects connected loads from surges, spikes, lightning, and other power disturbances.

Input Power Factor Correction

Minimizes installation costs by enabling the use of smaller generators and cabling.

Generator Compatible

Ensures clean, uninterrupted power to protected equipment when generator power is used.

Cold-Start Capable

Provides temporary battery power when the utility power is out.

Resettable Circuit Breaker

Easy recovery from overloads; no need to replace a fuse.

Adaptability

Flash Upgradeable Firmware

Install maintenance releases of firmware remotely using FTP.

Plug-and-Play External Batteries

Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.

Serviceability

Automatic Self-Test

Periodic battery self-test ensures early detection of a battery that needs to be replaced.

User-Replaceable Batteries

Increases availability by allowing a trained user to perform upgrades and replacements of the batteries, thus reducing the Mean Time to Repair (MTTR).

Disconnected Battery Notification

Warns when a battery is not available to provide backup power.

Predictive Failure Notification

Provides early-warning fault analysis, ensuring proactive and component replacement.

Audible Alarms

Provides notification of changing utility power and UPS power conditions.

Specifications

7 groups · 37 specs

Total Outlets
10
Maximum Wattage
2700 W
Full-Load Runtime
4 Minutes

Reviews