1 / 3
$123.99
In stock
Free Standard shipping
Typically arrives in 4 business days
Quantity
Key specs
- Input Frequency
- 50/60 Hz ± 5 Hz (Auto Sensing)
- Output Frequency
- 50/60 Hz ± 1 Hz
- Rackmount Size
- No
- Dimensions (W x H x D)
- 4.13 x 5.47 x 12.87" / 10.49 x 13.89 x 32.69 cm
- Weight
- 8.38 lb / 3.8 kg
- Total Outlets
- 9x NEMA 5-15R (3 Transformer-Sized)
Overview
Designed for electronics in your home or office, such as computers and related equipment, the Back-UPS BVN900M1 Battery Backup & Surge Protector from APC provides clean battery power when power is interrupted or fluctuates outside of expected levels. In the case of a power outage, it can provide up to 1.6 minutes of runtime at max load and 9.8 minutes at half load. It also provides an output capacity of 900 VA / 480W, nine total NEMA 5-15R outlets (six battery backup & surge and three surge-only), an input voltage of 120 VAC at 60 Hz ± 5 Hz using its 5' cord with a NEMA 5-15P plug, and a surge energy rating of 490 joules. Its sealed lead-acid battery is maintenance-free and can be recharged in 6-8 hours. Three of the battery & surge outlets and spaced widely to accommodate larger plugs, and there is also a 2.1A USB Type-A charging port that is MFi certified for smartphones and tablets.
To help ensure a long operational life, APC backs this UPS with a limited 3-year repair or replace warranty for the APC unit, a limited 1-year battery warranty, and a limited lifetime $75,000 equipment protection policy.
To help ensure a long operational life, APC backs this UPS with a limited 3-year repair or replace warranty for the APC unit, a limited 1-year battery warranty, and a limited lifetime $75,000 equipment protection policy.
General Features
USB Type-A Charging Port
The USB Type-A charging port is MFi certified and provides 2.1A for smartphones and tablets.Mute Button
The mute button allows for the simple silencing of the battery backup alarms.Adjustable Voltage Sensitivity
Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.Audible Alarms
Provides notification of changing utility power and UPS power conditions.Automatic Self-Test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.Battery Failure Notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance.Building Wiring Fault Indicator
This LED informs users of potentially dangerous wiring problems in the wall circuit.Cold-Start Capable
Provides temporary battery power when the utility power is out.Battery-Protected and Surge-Only Outlets
Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge-only protection for less critical equipmentSurge-Only Outlets
Protect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.LED Status Display
Quickly understand unit and power status with visual indicators.Intelligent Battery Management
Maximizes battery performance, life, and reliability through intelligent, precision charging.Safety-Agency Approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.Specifications
7 groups · 34 specs
- Total Outlets
- 9x NEMA 5-15R (3 Transformer-Sized)
- Plug Type
- NEMA 5-15P Right-Angle
- Surge Protection
- Yes: 490 Joules
- Maximum Wattage
- 480 W
- Full-Load Runtime
- 1.6 Minutes
- Total Outlets
- 9x NEMA 5-15R (3 Transformer-Sized)
- Plug Type
- NEMA 5-15P Right-Angle
- Surge Protection
- Yes: 490 Joules
- Maximum Wattage
- 480 W
- Full-Load Runtime
- 1.6 Minutes
- Total Outlets
- 9x NEMA 5-15R (3 Transformer-Sized)
- Protected Outlets
- 6x NEMA 5-15R (Battery and Surge) 3x NEMA 5-15R (Surge Only)
- Plug Type
- NEMA 5-15P Right-Angle
- USB Charging Ports
- 1x USB-A (2.1 A)
- Transfer Time
- 6 to 10 ms
- Surge Protection
- Yes: 490 Joules
- Current
- 10 A (Circuit Breaker Rating)
- Maximum Wattage
- 480 W
- Nominal Input Voltage
- 120 VAC
- Input Voltage Adjustable Range
- 88 to 143 VAC
- Input Frequency
- 50/60 Hz ± 5 Hz (Auto Sensing)
- Nominal Output Voltage
- 120 VAC
- Output Frequency
- 50/60 Hz ± 1 Hz
- Load Capacity
- 900 VA
- Waveform
- Simulated Sine Wave
- Battery Capacity
- (108 VaH)
- Chemistry
- Lead-Acid
- Full-Load Runtime
- 1.6 Minutes
- Half-Load Runtime
- 9.8 Minutes
- Recharge Time
- 6 to 8 Hours
- Operating Conditions
- 32 to 104°F / 0 to 40°C up to 90% Humidity
- Certifications
- CEC, CSA, FCC, UL, cTUVus
- Cable Length
- 5' / 1.5 m
- Rackmount Size
- No
- Dimensions (W x H x D)
- 4.13 x 5.47 x 12.87" / 10.49 x 13.89 x 32.69 cm
- Weight
- 8.38 lb / 3.8 kg
- Box Dimensions (LxWxH)
- 18.1 x 8.5 x 6.9"
- Package Weight
- 10.18 lb
- Warranty
- Available
Reviews
No reviews yet.
Write a review
Reviews are accepted from verified buyers.












