1 / 5
$1,349.10
In stock
Free Standard shipping
Typically arrives in 4 business days
Quantity
- For CINE VCLX, VCLX-CA, VCLXS Batteries
- Approximately 7 Hour Charge Time
- 100-240V Worldwide Compatibility
Key specs
- Power I/O
- 1x Proprietary Female Input • 100 to 240 VAC, 50 / 60 Hz 1x LEMO 19-Pin Female Output Included Power Adapter/Cable 1x Cable with USA Type-A/B Plug to Proprietary Male
- Dimensions
- 10.2 x 9.4 x 2.2" / 26 x 24 x 5.7 cm
- Weight
- 4.2 lb / 1.9 kg
- Charger Type
- 1x Charger Box for 1x Battery
- Compatibility
- Battery: Anton/Bauer CINE VCLX Power Station / Anton/Bauer CINE VCLX-CA Power Station / Anton/Bauer CINE VCLXS Power Station
- Indicator
- Status Light
Overview
The Anton/Bauer CINE VCLX Charger features a slim and portable design and allows you to charge the Anton/Bauer CINE VCLX, VCLX-CA, and VCLXS batteries. The Anton/Bauer CS-GBC Charger Cable, not included, is required for connecting the battery. The charger supports a single battery at a time via a LEMO output port, and charges it in approximately 7 hours.
Anton/Bauer CS-GBC Charger Cable (not included) is required for connecting the battery.
Full InterActive technology including six simultaneous charge termination systems, Balance and Rejuvenation modes, and LifeSaver Maintenance mode. InterActive communication between battery and charger, which allows the charger to identify the cell packs and determine the precise charge routine for that cell pack under the prevailing conditions. This information is communicated to the charger by the battery and is incorporated, through specialized programming and algorithms to optimize the charging of the battery.
Worldwide Compatibility
Wide range mains input compatibility (100-240 VAC 50-60 Hz) automatically adapts to any mains source worldwide.
Charge Status
Red and green LEDs for charge status - red and green alternating, steady red, flashing red, and steady green.
Stage 1
Stage 1 will deliver a charge matched to the capabilities of the battery. During this stage, six separate cutoff methods are in operation, simultaneously, ensuring the fastest, safest charge for that battery.
Stage 2
Stage 2 charging is a balancing or "equalize" mode which calculates each battery pack type to offset any imbalance of the battery's cells, created by unequal self-discharge or any capacity mismatch of the individual cells in the pack. This stage can vary in duration from zero to as much as 16 hours, depending on the condition of the battery. A battery will typically leave Stage 2 in 2-4 hours under average operating conditions.
Stage 3
Stage 3 charging is the Anton/Bauer exclusive Lifesaver maintenance mode. This patented pulse routine keeps batteries fully charged, free from self-discharge - indefinitely - without damaging heat associated with so-called "trickle charge".
Key Features
InterActive TechnologyFull InterActive technology including six simultaneous charge termination systems, Balance and Rejuvenation modes, and LifeSaver Maintenance mode. InterActive communication between battery and charger, which allows the charger to identify the cell packs and determine the precise charge routine for that cell pack under the prevailing conditions. This information is communicated to the charger by the battery and is incorporated, through specialized programming and algorithms to optimize the charging of the battery.
Worldwide Compatibility
Wide range mains input compatibility (100-240 VAC 50-60 Hz) automatically adapts to any mains source worldwide.
Charge Status
Red and green LEDs for charge status - red and green alternating, steady red, flashing red, and steady green.
Three-Stage Charging Methodology
In general, the CINE VCLX Charger will deliver a three-stage charge routine to each battery.Stage 1
Stage 1 will deliver a charge matched to the capabilities of the battery. During this stage, six separate cutoff methods are in operation, simultaneously, ensuring the fastest, safest charge for that battery.
Stage 2
Stage 2 charging is a balancing or "equalize" mode which calculates each battery pack type to offset any imbalance of the battery's cells, created by unequal self-discharge or any capacity mismatch of the individual cells in the pack. This stage can vary in duration from zero to as much as 16 hours, depending on the condition of the battery. A battery will typically leave Stage 2 in 2-4 hours under average operating conditions.
Stage 3
Stage 3 charging is the Anton/Bauer exclusive Lifesaver maintenance mode. This patented pulse routine keeps batteries fully charged, free from self-discharge - indefinitely - without damaging heat associated with so-called "trickle charge".
Specifications
3 groups · 9 specs
- Charger Type
- 1x Charger Box for 1x Battery
- Compatibility
- Battery: Anton/Bauer CINE VCLX Power Station / Anton/Bauer CINE VCLX-CA Power Station / Anton/Bauer CINE VCLXS Power Station
- Power I/O
- 1x Proprietary Female Input • 100 to 240 VAC, 50 / 60 Hz 1x LEMO 19-Pin Female Output Included Power Adapter/Cable 1x Cable with USA Type-A/B Plug to Proprietary Male
- Indicator
- Status Light
- Features
- Diagnostics Function
- Dimensions
- 10.2 x 9.4 x 2.2" / 26 x 24 x 5.7 cm
- Weight
- 4.2 lb / 1.9 kg
- Charger Type
- 1x Charger Box for 1x Battery
- Compatibility
- Battery: Anton/Bauer CINE VCLX Power Station / Anton/Bauer CINE VCLX-CA Power Station / Anton/Bauer CINE VCLXS Power Station
- Power I/O
- 1x Proprietary Female Input • 100 to 240 VAC, 50 / 60 Hz 1x LEMO 19-Pin Female Output Included Power Adapter/Cable 1x Cable with USA Type-A/B Plug to Proprietary Male
- Indicator
- Status Light
- Features
- Diagnostics Function
- Dimensions
- 10.2 x 9.4 x 2.2" / 26 x 24 x 5.7 cm
- Weight
- 4.2 lb / 1.9 kg
- Package Weight
- 6.04 lb
- Warranty
- Available
Reviews
No reviews yet.
Write a review
Reviews are accepted from verified buyers.